Drug Screen Dipstick Test

Drugs of Abuse Test Cut-off Levels:
| Amphetamines (AMP) | 1000 ng/ml |
| Barbiturates (BAR) | 300 ng/ml |
| Benzodiazepines (BZO) | 300 ng/ml |
| Cocaine (COC) | 300 ng/ml |
| Ecstasy (MDMA) | 500 ng/ml |
| Marijuana (THC) | 50 ng/ml |
| Methadone (MTD) | 300 ng/ml |
| Methamphetamines (MET) | 500 ng/ml |
| Opiates (OPI) | 300 ng/ml |
| Oxycodone (OXY) |
100 ng/ml |
| Phencyclidine (PCP | 25 ng/ml |
| Tricyclic Antidepressants (TCA) | 1000 ng/ml |
| Coming Soon: | |
| Buprenorphine (BUP) | 5 ng/ml |
- Single and Multiple drugs of abuse dipstick tests
- CLIA-Waived device
- 12 Drugs available
- Simultaneous detection of 1-4 drugs
- Able to customize according to your needs
- One-step qualitative assay
- User-friendly, reliable, accurate at reasonable cost
- Easy interpretation of results (5 min or less)
- FDA cleared
Fastect® II Reference Guide
The Fastect® II Drug Screen Dipstick Test is a simple one-step dipstick device for the rapid qualitative detection of drugs of abuse in human urine.
Fastect® II Procedures
-
Remove the Fastect® II test device from the sealed pouch and slide the protective sleeve all the way up.

-
Dip the sample pad of the test device into the urine specimen to the maximum dip level for at least 10 seconds. Dip up to and not beyond the tips of the arrows.
-
Slide the sleeve down to the read indicator mark and lay the device on a level surface.

-
Read the results once the control band (C) appears (in approximately 5 minutes). Results may be interpreted up to 1 hour. Do not read after 1 hour.
Interpreting Fastect® II Test Results
Invalid ResultWhen no band appears in the CONTROL (C) region, the test is invalid even if there is a band in the test region. Check testing procedures, and samples. Repeat the test with a new device. Example Interpretation:
|
Negative ResultFor each test, two colored bands should be observed:
The color of the test band may be slightly darker or lighter than the control band. Any band that can be seen visually is a negative result. Example Interpretation:
|
Presumptive Positive ResultA colored band at the CONTROL (C) region should be observed. When there is no colored band at the specific TEST region, the test is presumptive positive for that particular drug. Example Interpretation:
|
Single Drug Dip Devices
| CAT# | Description | Tests / box |
|---|---|---|
| MF10 | THC 50 | 50 |
| MF11 | COC 300 | 50 |
| MF13 | OPI 300 | 50 |
| MF14 | AMP 100 | 50 |
| MF16 | MET 500 | 50 |
| MF17 | PCP 25 | 50 |
| MF18 | BZO 300 | 50 |
| MF19 | BAR 300 | 50 |
| MF20 | MTD 300 | 50 |
| MF22 | MDMA 500 | 50 |
| MF23 | OXY 100 | 50 |
Multiple Drug Dip Devices
| CAT# | Description | Tests / box |
|---|---|---|
| BF10 | THC 50 / COC 300 | 50 |
| BF13 | THC 50 / MET 500 | 50 |
| BF16 | THC 50 / OPI 300 | 50 |
| TF12 | THC 50 / MET 500 / OPI 300 | 50 |
| TF13 | THC 50 / COC 300 / OPI 300 | 50 |
| TF16 | THC 50 / COC 300 / MET 500 | 50 |
| TF19 | THC 50 / COC 300 / BZO 300 | 50 |
| TF23 | THC 50 / COC 300 / OXY 100 | 50 |
| QF09 | THC 50 / COC 300 / OPI 300 / BZO 300 | 50 |
| QF10 | THC 50 / COC 300 / OPI 300 / MTD 300 | 50 |
| QF12 | THC 50 / COC 300 / OPI 300 / MET 500 | 50 |