Agriyork 400 Limited

5 Lockwood Court, Market Place

Pocklington

YO42 2QW

T) +44 (0)1759 306580

E) sales@agriyork.co.uk

ToxCup™

< BACK

Collect, lean, test, and ship - all in a single, easy to use device.     Contact Agriyork at sales@agriyork.co.uk to find out how to obtain demo samples of our new EU ToxCup

The ToxCup™ integrates urine collection, testing and shipping into one device. Active in 10 seconds. Runs within 2-5 minutes. Available with built in adulterant tests to ensure sample integrity.

Test for the following Drugs of Abuse:

  • Amphetamines
  • Cocaine
  • Marijuana
  • Methamphetamines
  • Opiates
  • PCP

Test for the following Adulterants: *

  • Oxidizing Agents
  • pH
  • Creatinine
  • Nitrite

The Facts

  • Rapid one-step procedure: lean and read
  • Completes 5 drug tests in 5 minutes
  • No Sample exposure
  • Integrates sample collection, testing, and shipping for confirmation in a single container
  • Simple visual results
  • Room temperature storage
  • Convenient: fits most laboratory trays
  • Multiple test configurations
  • Simultaneously tests for adulterants
  • Temperature strip included

Cut Off Levels (Drugs)

Cut Off Levels (Drugs)
Amphetamines (AMP) 1000 ng/ml
Cocaine (COC) 300 ng/ml
Marijuana (THC) 50 ng/ml
Methamphetimines (MET) 500 & 1000 ng/ml
Opiates (OPI) 300 & 2000 ng / ml
Phencyclidine (PCP) 25 ng/ml

Cut Off Levels (Adulterants)

*Coming soon

OX (oxidizing agents) form color from blue to brown black when agents such as bleach, nitrite and pyridinium chlorochromate are present.

pH values below 4.0 and above 11.0 indicate adulteration. Pad changes color from orange (low), green (normal), brown (high).

CR creatinine low levels are indicative of dilution. The color intensity is directly proportional to the concentration of creatinine in the urine.

Ni nitrite levels of up to 3.6 mg/dl may be found in some urine specimens. Nitrite pad changes from no color to pink (normal) to dark purple (abnormal) above 50 mg/dl.

The Procedure

  1. Twist test lid onto specimen cup after collection.

  2. Lean cup on side to activate testing.

  3. Read results. Control band must be present for test to be valid.

Multiple Drug Screen Cup Test

Multiple Drug Screen Cup Test
CAT# Description Tests / box
PT11 AMP 1000 / COC 300 / OPI 2000 / PCP 25 / THC 50 25
PT12 COC 300 / MET 500 / OPI 2000 / PCP 25 / THC 50 25
PT15 AMP 1000 / COC 300 / MET 500 / OPI 300 / THC 50 25
PT11A COC 300 / AMP 1000 / OPI 2000 / PCP 25 / THC 50 & CR/NI, pH/OX 25
PT12A COC 300 / MET 500 / OPI 2000 / PCP 25 / THC 50 & CR/NI, pH/OX 25
PT15A AMP 1000 / COC 300 / MET 500 / OPI 300 / THC 50 & CR/NI, pH/OX 25